Deprecated: Return type of DrupalCacheArray::offsetExists($offset) should either be compatible with ArrayAccess::offsetExists(mixed $offset): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/rprlib/prod72/www/includes/bootstrap.inc on line 362
Deprecated: Return type of DrupalCacheArray::offsetGet($offset) should either be compatible with ArrayAccess::offsetGet(mixed $offset): mixed, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/rprlib/prod72/www/includes/bootstrap.inc on line 369
Deprecated: Return type of DrupalCacheArray::offsetSet($offset, $value) should either be compatible with ArrayAccess::offsetSet(mixed $offset, mixed $value): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/rprlib/prod72/www/includes/bootstrap.inc on line 381
Deprecated: Return type of DrupalCacheArray::offsetUnset($offset) should either be compatible with ArrayAccess::offsetUnset(mixed $offset): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/rprlib/prod72/www/includes/bootstrap.inc on line 388 peek acuity
https://www.rpr.lib.ok.us/taxonomy/term/3170/all
enVisual Acuity Assessment and Vision Screening Using a Novel Smartphone Application
https://www.rpr.lib.ok.us/resource/visual-acuity-assessment-and-vision-screening-using-novel-smartphone-application
<div class="field field-name-field-artifact-uploaded-date field-type-datetime field-label-inline clearfix">
<div class="field-label">Date Added: </div>
<div class="field-items">
<div class="field-item even"><span class="date-display-single" property="dc:date" datatype="xsd:dateTime" content="2019-09-26T00:00:00-05:00">September 26, 2019</span></div>
</div>
</div>
<div class="field field-name-field-artifact-journal field-type-text field-label-inline clearfix">
<div class="field-label">Journal/Publication: </div>
<div class="field-items">
<div class="field-item even">The Journal of Pediatrics</div>
</div>
</div>
<div class="field field-name-field-artifact-publisher field-type-text field-label-inline clearfix">
<div class="field-label">Publisher: </div>
<div class="field-items">
<div class="field-item even">Elsevier, Inc.</div>
</div>
</div>
<div class="field field-name-field-artifact-published-date field-type-datetime field-label-inline clearfix">
<div class="field-label">Publication Date: </div>
<div class="field-items">
<div class="field-item even"><span class="date-display-single" property="dc:date" datatype="xsd:dateTime" content="2019-10-01T00:00:00-05:00">October 1, 2019</span></div>
</div>
</div>
<div class="field field-name-field-artifact-volume field-type-text field-label-inline clearfix">
<div class="field-label">Volume: </div>
<div class="field-items">
<div class="field-item even">213</div>
</div>
</div>
<div class="field field-name-field-artifact-pages field-type-text field-label-inline clearfix">
<div class="field-label">Pages: </div>
<div class="field-items">
<div class="field-item even">203-210</div>
</div>
</div>
<div class="field field-name-field-artifact-url field-type-link-field field-label-inline clearfix">
<div class="field-label">URL: </div>
<div class="field-items">
<div class="field-item even"><a href="https://www.ncbi.nlm.nih.gov/pubmed/31326117" target="_blank">Visual Acuity Assessment and Vision Screening Using a Novel Smartphone Application</a></div>
</div>
</div>
<div class="field field-name-field-artifact-type field-type-taxonomy-term-reference field-label-inline clearfix">
<div class="field-label">Type: </div>
<div class="field-items">
<div class="field-item even">Clinical Research Results, Best Local Practices</div>
</div>
</div>
<div class="field field-name-field-artifact-format field-type-taxonomy-term-reference field-label-inline clearfix">
<div class="field-label">Format: </div>
<div class="field-items">
<div class="field-item even">Article</div>
</div>
</div>
<div class="field field-name-field-artifact-doi-1 field-type-text field-label-inline clearfix">
<div class="field-label">DOI (1): </div>
<div class="field-items">
<div class="field-item even">10.1016/j.jpeds.2019.06.021</div>
</div>
</div>
<div class="field field-name-field-artifact-keywords field-type-taxonomy-term-reference field-label-above">
<div class="field-label">Keywords </div>
<div class="field-items">
<div class="field-item even"><a href="/tags/peek-acuity" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">peek acuity</a></div>
<div class="field-item odd"><a href="/tags/preschool-age-children" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">preschool-age children</a></div>
<div class="field-item even"><a href="/tags/school-age-children" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">school-age children</a></div>
<div class="field-item odd"><a href="/tags/vision-screening" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">vision screening</a></div>
</div>
</div>
<div class="field field-name-field-artifact-pmid-1 field-type-text field-label-inline clearfix">
<div class="field-label">PMID (1): </div>
<div class="field-items">
<div class="field-item even">31326117</div>
</div>
</div>
<div class="field field-name-field-artifact-mesh field-type-taxonomy-term-reference field-label-above">
<div class="field-label">MeSH </div>
<div class="field-items">
<div class="field-item even"><a href="/mesh/child" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">child</a></div>
<div class="field-item odd"><a href="/mesh/child-preschool" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">child, preschool</a></div>
<div class="field-item even"><a href="/mesh/humans" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">Humans</a></div>
<div class="field-item odd"><a href="/mesh/ophthalmology" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">ophthalmology</a></div>
<div class="field-item even"><a href="/mesh/smarthphone" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">smarthphone</a></div>
<div class="field-item odd"><a href="/mesh/vision" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">vision</a></div>
<div class="field-item even"><a href="/mesh/low" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">low</a></div>
<div class="field-item odd"><a href="/mesh/visual-acuity" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">visual acuity</a></div>
<div class="field-item even"><a href="/mesh/eye" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">eye</a></div>
</div>
</div>
<div class="field field-name-field-artifact-editor-note field-type-text-long field-label-hidden">
<div class="field-items">
<div class="field-item even"><p>There are a wide variety of apps that could be useful for vision exams. I couldn’t find the Peek Acuity app though. James W. Mold, MD, MPH</p>
</div>
</div>
</div>
<div class="field field-name-field-artifact-text-availability field-type-list-text field-label-hidden">
<div class="field-items">
<div class="field-item even">Commercial full text (fees may apply)</div>
</div>
</div>
<div class="field field-name-field-artifact-document-content field-type-entityreference field-label-hidden">
<div class="field-items">
<div class="field-item even"><div class="view view-artifact-docs view-id-artifact_docs view-display-id-block view-dom-id-f6eb0781dc7f37597dd56652e6465157">
<div class="view-content">
<div class="views-row views-row-1 views-row-odd views-row-first views-row-last">
<a href="https://www.ncbi.nlm.nih.gov/pubmed/31326117" class="btn btn-primary" target="_blank">View</a> </div>
</div>
</div></div>
</div>
</div>
<div class="field field-name-body field-type-text-with-summary field-label-hidden">
<div class="field-items">
<div class="field-item even" property="content:encoded"><p>OBJECTIVES:</p>
<p>To evaluate a smartphone-based application's (Peek Acuity) ability to assess visual acuity and screen for ocular conditions in children, we compared visual acuity assessment between Peek Acuity and the pediatric ophthalmology examination and evaluated Peek Acuity's ability to identify children with referable ocular conditions.</p>
<p>STUDY DESIGN:</p>
<p>We prospectively recruited 111 children age 3-17 years, presenting to a pediatric ophthalmology clinic, who could follow instructions. Monocular visual acuity assessments by Peek Acuity and standard clinical methods were performed in randomized order. We compared visual acuity assessments between methods using intraclass correlation coefficient (ICC) and evaluated Peek Acuity's ability to identify children with referable ocular conditions.</p>
<p>RESULTS:</p>
<p>ICC comparing visual acuity assessed between methods was 0.88 (95% CI 0.83-0.92) for first and 0.85 (95% CI 0.78-0.89) for second eyes examined. ICC among 3 to 5-year-olds (preschool-age children) was 0.88 (95% CI 0.77-0.94) for first and 0.45 (95% CI 0.13-0.68) for second eyes examined. Peek Acuity had a sensitivity of 83%-86% for decreased vision and 69%-83% for referable ocular disease. Sensitivity was highest among 3 to 5-year-olds with decreased vision, 93%-100%.</p>
<p>CONCLUSIONS:</p>
<p>Overall, Peek Acuity visual acuity assessment correlated well with visual acuity assessed by standard clinical methods, though preschool-age children appeared more susceptible to examination fatigue. Peek Acuity performed adequately as a screening tool and had the greatest sensitivity among those with decreased vision and preschool-age children.</p>
<p>TRIAL REGISTRATION:</p>
<p>ClinicalTrials.gov: <a href="http://clinicaltrials.gov/show/NCT03212222" title="See in ClinicalTrials.gov">NCT03212222</a>.</p>
</div>
</div>
</div>
<div class="field field-name-field-resource-author field-type-taxonomy-term-reference field-label-inline clearfix">
<div class="field-label">Author/s: </div>
<div class="field-items">
<div class="field-item even">Zhao, L, Stinnett, SS, Prakalapakom, SG</div>
</div>
</div>
Thu, 26 Sep 2019 13:29:35 +0000John Bayhi758 at https://www.rpr.lib.ok.us