Deprecated: Return type of DrupalCacheArray::offsetExists($offset) should either be compatible with ArrayAccess::offsetExists(mixed $offset): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/rprlib/prod72/www/includes/bootstrap.inc on line 362

Deprecated: Return type of DrupalCacheArray::offsetGet($offset) should either be compatible with ArrayAccess::offsetGet(mixed $offset): mixed, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/rprlib/prod72/www/includes/bootstrap.inc on line 369

Deprecated: Return type of DrupalCacheArray::offsetSet($offset, $value) should either be compatible with ArrayAccess::offsetSet(mixed $offset, mixed $value): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/rprlib/prod72/www/includes/bootstrap.inc on line 381

Deprecated: Return type of DrupalCacheArray::offsetUnset($offset) should either be compatible with ArrayAccess::offsetUnset(mixed $offset): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/rprlib/prod72/www/includes/bootstrap.inc on line 388
sphygmomanometers https://www.rpr.lib.ok.us/taxonomy/term/1553/all en Comparing Automated Office Blood Pressure Readings With Other Methods of Blood Pressure Measurement for Identifying Patients With Possible Hypertension: A Systematic Review and Meta-analysis https://www.rpr.lib.ok.us/resource/comparing-automated-office-blood-pressure-readings-other-methods-blood-pressure-measurement <div class="field field-name-field-artifact-uploaded-date field-type-datetime field-label-inline clearfix"> <div class="field-label">Date Added:&nbsp;</div> <div class="field-items"> <div class="field-item even"><span class="date-display-single" property="dc:date" datatype="xsd:dateTime" content="2019-02-17T00:00:00-06:00">February 17, 2019</span></div> </div> </div> <div class="field field-name-field-artifact-journal field-type-text field-label-inline clearfix"> <div class="field-label">Journal/Publication:&nbsp;</div> <div class="field-items"> <div class="field-item even">JAMA Internal Medicine</div> </div> </div> <div class="field field-name-field-artifact-publisher field-type-text field-label-inline clearfix"> <div class="field-label">Publisher:&nbsp;</div> <div class="field-items"> <div class="field-item even">American Medical Association</div> </div> </div> <div class="field field-name-field-artifact-published-date field-type-datetime field-label-inline clearfix"> <div class="field-label">Publication Date:&nbsp;</div> <div class="field-items"> <div class="field-item even"><span class="date-display-single" property="dc:date" datatype="xsd:dateTime" content="2019-02-04T00:00:00-06:00">February 4, 2019</span></div> </div> </div> <div class="field field-name-field-artifact-url field-type-link-field field-label-inline clearfix"> <div class="field-label">URL:&nbsp;</div> <div class="field-items"> <div class="field-item even"><a href="https://www.ncbi.nlm.nih.gov/pubmed/30715088" target="_blank">Comparing Automated Office Blood Pressure Readings With Other Methods of Blood Pressure Measurement for Identifying Patients With Possible Hypertension: A Systematic Review and Meta-analysis.</a></div> </div> </div> <div class="field field-name-field-artifact-type field-type-taxonomy-term-reference field-label-inline clearfix"> <div class="field-label">Type:&nbsp;</div> <div class="field-items"> <div class="field-item even">Meta-analyses, Reviews, and Guidelines</div> </div> </div> <div class="field field-name-field-artifact-doi-1 field-type-text field-label-inline clearfix"> <div class="field-label">DOI (1):&nbsp;</div> <div class="field-items"> <div class="field-item even">10.1001/jamainternmed.2018.6551</div> </div> </div> <div class="field field-name-field-artifact-keywords field-type-taxonomy-term-reference field-label-above"> <div class="field-label">Keywords&nbsp;</div> <div class="field-items"> <div class="field-item even"><a href="/tags/blood-pressure" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">blood pressure</a></div> </div> </div> <div class="field field-name-field-artifact-pmid-1 field-type-text field-label-inline clearfix"> <div class="field-label">PMID (1):&nbsp;</div> <div class="field-items"> <div class="field-item even">30715088</div> </div> </div> <div class="field field-name-field-artifact-mesh field-type-taxonomy-term-reference field-label-above"> <div class="field-label">MeSH&nbsp;</div> <div class="field-items"> <div class="field-item even"><a href="/mesh/blood-pressure" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">blood pressure</a></div> <div class="field-item odd"><a href="/mesh/sphygmomanometers" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">sphygmomanometers</a></div> </div> </div> <div class="field field-name-field-artifact-editor-note field-type-text-long field-label-hidden"> <div class="field-items"> <div class="field-item even"><p>Based on the evidence, automated office blood pressure measurement should now be the preferred method for recording BP in routine clinical practice.</p> </div> </div> </div> <div class="field field-name-field-artifact-text-availability field-type-list-text field-label-hidden"> <div class="field-items"> <div class="field-item even">Commercial full text (fees may apply)</div> </div> </div> <div class="field field-name-field-artifact-document-content field-type-entityreference field-label-hidden"> <div class="field-items"> <div class="field-item even"><div class="view view-artifact-docs view-id-artifact_docs view-display-id-block view-dom-id-1e09fe26366e9604404c49dfff49b775"> <div class="view-content"> <div class="views-row views-row-1 views-row-odd views-row-first views-row-last"> <a href="https://www.ncbi.nlm.nih.gov/pubmed/30715088" class="btn btn-primary" target="_blank">View</a> </div> </div> </div></div> </div> </div> <div class="field field-name-body field-type-text-with-summary field-label-hidden"> <div class="field-items"> <div class="field-item even" property="content:encoded"><p>IMPORTANCE:</p> <p>Automated office blood pressure (AOBP) measurement involves recording several blood pressure (BP) readings using a fully automated oscillometric sphygmomanometer with the patient resting alone in a quiet place. Although several studies have shown AOBP measurement to be more accurate than routine office BP measurement and not subject to a "white coat effect," the cumulative evidence has not yet been systematically reviewed.</p> <p>OBJECTIVE:</p> <p>To perform a systematic review and meta-analysis to examine the association between AOBP and office BP readings measured in routine clinical practice and in research studies, and ambulatory BP recorded during awake hours, as the latter is a standard for predicting future cardiovascular events.</p> <p>DATA SOURCES:</p> <p>The MEDLINE, Embase, and Cochrane Library were searched from 2003 to April 25, 2018.</p> <p>STUDY SELECTION:</p> <p>Studies on systolic and diastolic BP measurement by AOBP in comparison with awake ambulatory BP, routine office BP, and research BP measurements were included if they contained 30 patients or more.</p> <p>DATA EXTRACTION AND SYNTHESIS:</p> <p>Study characteristics were abstracted independently and random effects meta-analyses and meta-regressions were conducted.</p> <p>MAIN OUTCOMES AND MEASURES:</p> <p>Pooled mean differences (95% CI) of systolic and diastolic BP between types of BP measurement.</p> <p>RESULTS:</p> <p>Data were compiled from 31 articles comprising 9279 participants (4736 men and 4543 women). In samples with systolic AOBP of 130 mm Hg or more, routine office and research systolic BP readings were substantially higher than AOBP readings, with a pooled mean difference of 14.5 mm Hg (95% CI, 11.8-17.2 mm Hg; n = 9; I2 = 94.3%; P &lt; .001) for routine office systolic BP readings and 7.0 mm Hg (95% CI, 4.9-9.1 mm Hg; n = 9; I2 = 85.7%; P &lt; .001) for research systolic BP readings. Systolic awake ambulatory BP and AOBP readings were similar, with a pooled mean difference of 0.3 mm Hg (95% CI, -1.1 to 1.7 mm Hg; n = 19; I2 = 90%; P &lt; .001).</p> <p>CONCLUSIONS AND RELEVANCE:</p> <p>Automated office blood pressure readings, only when recorded properly with the patient sitting alone in a quiet place, are more accurate than office BP readings in routine clinical practice and are similar to awake ambulatory BP readings, with mean AOBP being devoid of any white coat effect. There has been some reluctance among physicians to adopt this technique because of uncertainty about its advantages compared with more traditional methods of recording BP during an office visit. Based on the evidence, AOBP should now be the preferred method for recording BP in routine clinical practice.</p> </div> </div> </div> <div class="field field-name-field-resource-author field-type-taxonomy-term-reference field-label-inline clearfix"> <div class="field-label">Author/s:&nbsp;</div> <div class="field-items"> <div class="field-item even">Roerecke, Michael, Kaczorowski, Janusz, Myers, Martin G.</div> </div> </div> Mon, 18 Feb 2019 00:05:21 +0000 Jeffrey Wilson 383 at https://www.rpr.lib.ok.us