Deprecated: Return type of DrupalCacheArray::offsetExists($offset) should either be compatible with ArrayAccess::offsetExists(mixed $offset): bool, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/rprlib/prod72/www/includes/bootstrap.inc on line 362

Deprecated: Return type of DrupalCacheArray::offsetGet($offset) should either be compatible with ArrayAccess::offsetGet(mixed $offset): mixed, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/rprlib/prod72/www/includes/bootstrap.inc on line 369

Deprecated: Return type of DrupalCacheArray::offsetSet($offset, $value) should either be compatible with ArrayAccess::offsetSet(mixed $offset, mixed $value): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/rprlib/prod72/www/includes/bootstrap.inc on line 381

Deprecated: Return type of DrupalCacheArray::offsetUnset($offset) should either be compatible with ArrayAccess::offsetUnset(mixed $offset): void, or the #[\ReturnTypeWillChange] attribute should be used to temporarily suppress the notice in /home/rprlib/prod72/www/includes/bootstrap.inc on line 388
myopia https://www.rpr.lib.ok.us/taxonomy/term/11332/all en Digital Screen Time and Myopia: A Systematic Review and Dose-Response Meta-Analysis https://www.rpr.lib.ok.us/resource/digital-screen-time-and-myopia-systematic-review-and-dose-response-meta-analysis <div class="field field-name-field-artifact-uploaded-date field-type-datetime field-label-inline clearfix"> <div class="field-label">Date Added:&nbsp;</div> <div class="field-items"> <div class="field-item even"><span class="date-display-single" property="dc:date" datatype="xsd:dateTime" content="2025-02-27T00:00:00-06:00">February 27, 2025</span></div> </div> </div> <div class="field field-name-field-artifact-journal field-type-text field-label-inline clearfix"> <div class="field-label">Journal/Publication:&nbsp;</div> <div class="field-items"> <div class="field-item even">JAMA</div> </div> </div> <div class="field field-name-field-artifact-published-date field-type-datetime field-label-inline clearfix"> <div class="field-label">Publication Date:&nbsp;</div> <div class="field-items"> <div class="field-item even"><span class="date-display-single" property="dc:date" datatype="xsd:dateTime" content="2025-02-03T00:00:00-06:00">February 3, 2025</span></div> </div> </div> <div class="field field-name-field-artifact-url field-type-link-field field-label-inline clearfix"> <div class="field-label">URL:&nbsp;</div> <div class="field-items"> <div class="field-item even"><a href="https://pubmed.ncbi.nlm.nih.gov/39982728/" target="_blank">Digital Screen Time and Myopia: A Systematic Review and Dose-Response Meta-Analysis</a></div> </div> </div> <div class="field field-name-field-artifact-type field-type-taxonomy-term-reference field-label-inline clearfix"> <div class="field-label">Type:&nbsp;</div> <div class="field-items"> <div class="field-item even">Meta-analyses, Reviews, and Guidelines</div> </div> </div> <div class="field field-name-field-artifact-format field-type-taxonomy-term-reference field-label-inline clearfix"> <div class="field-label">Format:&nbsp;</div> <div class="field-items"> <div class="field-item even">Article</div> </div> </div> <div class="field field-name-field-artifact-doi-1 field-type-text field-label-inline clearfix"> <div class="field-label">DOI (1):&nbsp;</div> <div class="field-items"> <div class="field-item even">10.1001/jamanetworkopen.2024.60026</div> </div> </div> <div class="field field-name-field-artifact-keywords field-type-taxonomy-term-reference field-label-above"> <div class="field-label">Keywords&nbsp;</div> <div class="field-items"> <div class="field-item even"><a href="/tags/screen-time" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">screen time</a></div> <div class="field-item odd"><a href="/tags/myopia" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">myopia</a></div> </div> </div> <div class="field field-name-field-artifact-pmid-1 field-type-text field-label-inline clearfix"> <div class="field-label">PMID (1):&nbsp;</div> <div class="field-items"> <div class="field-item even">39982728</div> </div> </div> <div class="field field-name-field-artifact-mesh field-type-taxonomy-term-reference field-label-above"> <div class="field-label">MeSH&nbsp;</div> <div class="field-items"> <div class="field-item even"><a href="/mesh/screen-time-0" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">Screen Time*</a></div> <div class="field-item odd"><a href="/mesh/myopia-epidemiology" typeof="skos:Concept" property="rdfs:label skos:prefLabel" datatype="">Myopia* / epidemiology</a></div> </div> </div> <div class="field field-name-field-artifact-editor-note field-type-text-long field-label-hidden"> <div class="field-items"> <div class="field-item even"><p>Screen appears to be associated in a dose response pattern with myopia. Perhaps another argument to use with parents though causation has not been firmly established. James W. Mold, MD, MPH</p> </div> </div> </div> <div class="field field-name-field-artifact-text-availability field-type-list-text field-label-hidden"> <div class="field-items"> <div class="field-item even">Free full text</div> </div> </div> <div class="field field-name-field-artifact-document-content field-type-entityreference field-label-hidden"> <div class="field-items"> <div class="field-item even"><div class="view view-artifact-docs view-id-artifact_docs view-display-id-block view-dom-id-fa377f6e48c764570f9d273ae164ce42"> <div class="view-content"> <div class="views-row views-row-1 views-row-odd views-row-first views-row-last"> <a href="https://pubmed.ncbi.nlm.nih.gov/39982728/" class="btn btn-primary" target="_blank">View</a> </div> </div> </div></div> </div> </div> <div class="field field-name-body field-type-text-with-summary field-label-hidden"> <div class="field-items"> <div class="field-item even" property="content:encoded"><p>Importance: The association of digital screen time with myopia has been documented, but the dose-response association and safe exposure threshold remain unclear.</p> <p>Objective: To evaluate the dose-response association of time spent on digital screens with myopia risk.</p> <p>Data sources: PubMed, EMBASE, Cochrane Library databases, CINAHL, and ClinicalTrials.gov were searched for full-length articles from peer-reviewed journals without restrictions on study design, publication date, or language from inception to November 25, 2024.</p> <p>Study selection: Primary research articles investigating the association of exposure to digital screen devices (ie, smartphones, tablets, game consoles, computers, or television) with myopia-related outcomes (ie, prevalent or incident myopia and the rate of myopia progression) were identified by reviewers.</p> <p>Data extraction and synthesis: Two independent reviewers extracted data using a standardized procedure in accordance with the Meta-Analysis of Observational Studies in Epidemiology (MOOSE) and Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) reporting guidelines. A random-effects, dose-response meta-analysis (DRMA) was utilized to examine the pattern of the association of screen time with myopia.</p> <p>Main outcome and measures: Increased odds of myopia per hour of daily screen time.</p> <p>Results: In the linear DRMA of 45 studies with 335 524 participants (mean [SD] age, 9.3 [4.3] years), an additional hour of daily screen time was associated with higher odds of myopia (odds ratio [OR], 1.21; 95% CI, 1.13-1.30). The nonlinear DRMA of 34 studies with 314 910 participants also indicated higher odds of myopia with increasing screen time, ranging from 1 hour of daily exposure (OR, 1.05; 95% CI, 1.01-1.09) to 4 hours (OR, 1.97; 95% CI, 1.56-2.40). The dose-response curve showed myopia risk increasing significantly between 1 to 4 hours of daily screen time, and then rising more gradually after 4 hours.</p> <p>Conclusions and relevance: In this systematic review and DRMA, a daily 1-hour increment in digital screen time was associated with 21% higher odds of myopia and the dose-response pattern exhibited a sigmoidal shape, indicating a potential safety threshold of less than 1 hour per day of exposure, with an increase in odds up to 4 hours. These findings can offer guidance to clinicians and researchers regarding myopia risk.</p> </div> </div> </div> <div class="field field-name-field-resource-author field-type-taxonomy-term-reference field-label-inline clearfix"> <div class="field-label">Author/s:&nbsp;</div> <div class="field-items"> <div class="field-item even">Ahnul Ha, Yun Jeong Lee, Marvin Lee, Sung Ryul Shim, Young Kook Kim</div> </div> </div> Thu, 27 Feb 2025 17:47:38 +0000 Alex Haga 2571 at https://www.rpr.lib.ok.us